<aside> 💡 NOTE: The instructions in this section are only a quick summary of node installation procedures. It is necessary to read the system Mounting Recommendations Manual below for more detailed instructions and precautions on all system mounting options provided by greenteg.

</aside>

UWS-Mounting Recommendations Manual_v1.0.pdf

Caution: Sensor accuracy only performs as per specifications if greenteg mounting solutions are used. Any other non-greenteg approved mounting solutions will result in measurement errors and possibly even safety issues.

Optional: Use thermographic imaging to help identify representative/interesting spots for the heat flux sensor placement on your building element.

Node Mounting: For a U-Value / R-Value Measurement, mount an inner node (Type 1) configuration and outer node (Type 2) configuration on opposite sides of your building element. See "Nodes Overview" at beginning of manual for more information.

Connect an inner sensor with a temperature sensor to one node (type 1) and an outer sensor with another temperature sensor to another node (type 2). Be careful not to break any of the five pins on the sensor connector.

  1. Mount the node to the wall using the provided double-sided adhesive roll tapes, or place it on a suitable spot next to the wall (for example a shelf). Please ensure that the adhesive tape removal tabs stick out from the side of the measurement node.
  2. Mount the Inner sensor with a strip of double-sided adhesive roll tape.

NOTE: It is important that the removal tab points to the side of the sensor and not to the direction of the sensor cable. 3. Mount the ambient air temperature sensor using the provided sensor holder and one piece of double-sided adhesive tape.

Untitled

Untitled

Node Mounting

Ambient Clip Mounting

Untitled

                                                      Correct Mounting Setup